'BIO-OXYGEN'
AIR STERILIZATION & PURIFICATION EQUIPMENT


Model 8000
BIO-OXYGEN - The Intelligent Air Purifier
© Copyright Bio-Oxygen

ABSTRACT
Bio-Oxygen units are simply placed inside the air mixing plenum of an air handling unit where they continually decontaminate, disinfect and deodorize the supply air as the air mixes and flows through the mixing plenum. The units are interlocked with the supply fan of the air handling unit so that they automatically switch on/off with the supply fan, without fail.

APPLICATION
(a) for medium to large Central Air Conditioning Systems
(b) for medium to heavy Odour Control (Sewerage, Kitchen Exhaust, Garbage Rooms etc.).

MODEL 8000

CONTROLS & FEATURES (Manual & Auto Models)

* Provided on Manual and Auto Model. Other controls and features on Auto Model only.

ELECTRODE TUBES
Bio-Oxygen units are available with either 5 or 10 sockets. The Electrode Tubes simply screw into the sockets on the generator. Bio-Oxygen units are light and portable and may simply be unplugged and moved from AHU to AHU and from site to site. Electrode Tube Sizes: 150, 200, 250 and 300 mm. The size depends on available space in duct or plenum.

POSITIONING & ELECTRICAL WIRING
Bio-Oxygen units may easily be retro-fitted to any existing air conditioning unit without structural changes. An access panel in the return air plenum is required so that the Bio-Oxygen unit may be placed and accessed inside the plenum. A power point is required inside the plenum. The power point must be interlocked with the supply fan of the air handling unit so that the Bio-Oxygen unit switches on/off with the supply fan, without fail.

ELECTRODE TUBE EXCHANGE
The Bio-Oxygen equipment is only serviced if the Customer enters into An Electrode Exchange Agreement with Bio-Oxygen. The Electrode Exchange Agreement provides for:

Without an Electrode Exchange Agreement, Bio-Oxygen may service the equipment at Bio-Oxygen's sole discretion, without priority, at current service rates and provided that the customer has not tampered with the Bio-Oxygen equipment. The customer is responsible for the on-going replacement of the air filters specified by Bio-Oxygen.

Electrode Tube Exchange Charges
Under the Bio-Oxygen Electrode Exchange Contract, we exchange the Electrode Tubes when due and invoice the customer yearly.